Contents
- Introduction
- 1. Module Introduction
- 2. Introduction to Main Chips
- 2.1 Chip Overview
- 2.2 Pin Definitions
- 2.4 Performance Parameters
- 2.5 Communication Interfaces and Related Protocols
- 2.6 Register Definitions
- III. Circuit Engineering
- 3.1 Circuit Source Project
- 3.2 Module Usage Instructions
- 3.3 Application Experiment
- 4. Driver
- 5. BOM & Recommended Alternatives
- 6. Change History
- VII. Related Materials
Introduction
In scenarios such as frost formation on refrigerator evaporators, ice accumulation on fan blades, and road icing, the presence of frost and ice directly affects equipment efficiency and operational safety. However, traditional frost and ice detection solutions have never been able to overcome the industry pain points of "extensive control, high error rate, and high maintenance cost" - refrigerators generally use timed defrosting, which is forcibly activated regardless of the amount of frost, wasting energy and unable to handle abnormal thickening of the frost layer; in industrial scenarios, resistive and optical detection solutions are susceptible to contamination and condensation interference, with a high error rate, making it difficult to operate stably over the long term. Minyuan FDE Sensor Frost and Ice Sensor, with capacitive non-contact sensing technology, achieves accurate and quantitative frost/ice detection, providing reliable frost sensing solutions for various scenarios.

- Refrigerator / Home Appliance Scenario: Timed defrosting cannot be adjusted according to the actual amount of frost formation, either resulting in excessive defrosting and wasting electricity, or causing a decline in cooling efficiency due to untimely defrosting; the method of indirectly determining frost formation by temperature sensors is susceptible to ambient temperature, unable to quantify the thickness of the frost layer, and has poor control accuracy.
- Industrial/Outdoor Scenarios: Traditional resistive sensors are easily corroded and contaminated by frost and condensation, with a short service life; optical solutions are easily blocked and interfered with by reflections, with a high Error Rate; and most can only make qualitative judgments, unable to quantify the thickness of frost/ice layers, making it difficult to support refined control and early warning.
The emergence of the FDE Sensor, with capacitive sensing technology, has filled the gaps in these solutions.

Core Advantages of FDE Sensor - Precise, Reliable, and Easy-to-Integrate Frost Detection:
- ✅ Non-contact detection, quantifying frost thickness, and enabling more precise control: The FDE Sensor is based on the principle of capacitive sensing, integrating the high-precision differential capacitive sensing chip MDC04 from Minyuan. It determines the frost thickness through changes in dielectric constant, where the frost thickness is proportional to the capacitance value. It can detect frost layer thicknesses ≤10mm, with a resolution of 1mm. The built-in MCU detection processor can effectively filter out interference from temperature, electromagnetism, etc., quantify the amount of frost, and upgrade defrost control from "timed and extensive" to "precise on demand", which not only improves equipment efficiency but also reduces energy consumption.
- ✅ Strong anti-interference + wide temperature durability, capable of stable operation even in complex environments: The sensor supports a wide temperature Scope of Work from -40°C to +85°C, suitable for low-temperature environments in refrigerators and harsh conditions of outdoor industrial equipment; the non-contact design eliminates the need for direct contact with frost, fundamentally avoiding corrosion and contamination issues, ensuring stable detection performance even after long-term use without frequent maintenance.
- ✅ Low power consumption + easy installation, suitable for various types of scenarios:Operating power consumption is only 4.5mA@3.3V, with a supply voltage of 2V~5.5V, suitable for battery or device power supply; the sensor has a compact structure and can be directly installed close to the fins of the refrigerator evaporator without complex modifications; UART communication interface, convenient for integration into various types of devices, providing a convenient frost detection solution for household appliances and industrial equipment.
It can be used for:
- Refrigerator / Ice Maker Scenario: The "Precise Commander" of Intelligent Defrosting
- In devices such as refrigerator evaporators and ice makers, the FDE Sensor can be installed close to the fins to detect the frost thickness in real time. When the frost layer reaches the set threshold, it can trigger the defrosting program, enabling on-demand defrosting, avoiding energy waste associated with traditional timed defrosting, and preventing excessive frost from affecting refrigeration efficiency, thus making the refrigerator operate more energy-efficiently and ensuring more stable refrigeration performance.
- Industrial Fan / Tower Scenario: The "Frost Sentinel" of Equipment Safety
- In outdoor equipment such as wind turbine blades and power transmission towers, sensors can monitor icing/frosting conditions in real time, issue timely warnings, and prevent equipment damage and line failures caused by excessive frost and ice. The non-contact design is not affected by outdoor condensation and temperature changes, enabling long-term stable operation and providing all-weather monitoring for the safe operation of industrial equipment.
- Road / Outdoor Scenario: Reliable Sensing Unit for Ice Warning
- In the scenario of road icing detection, the FDE Sensor can be used to monitor the thickness of ice on the road surface, providing data support for road safety early warning; the sensor is not affected by road surface impurities or reflective interference, can accurately identify the icing state, and helps traffic management departments take anti-skid measures in a timely manner to ensure road traffic safety.
1. Module Introduction

This figure shows the module appearance and installation configuration of the FDE Sensor, facilitating understanding of its application location.
2. Introduction to Main Chips
2.1 Chip Overview
Minyuan High-Precision Differential Capacitive Sensing Chip MDC04 , determines the change in frost thickness by the change in dielectric constant, and the frost thickness is proportional to the capacitance value.
2.2 Pin Definitions

This diagram illustrates the pin definitions of the FDE module, which is used to complete the UART interface connection.
2.4 Performance Parameters

This figure presents the performance parameters of the FDE module, which can be used for power supply and measurement capability assessment.
2.5 Communication Interfaces and Related Protocols

This diagram shows the communication basic parameters and protocol format, which is the foundation for implementing host communication.

This figure supplements an example of communication readings to help understand how to query temperature and capacitance data.

This figure shows more communication example content, which can be used to compare and debug the frames sent by the host and the response frames.
2.6 Register Definitions

This figure lists the main register addresses and field meanings of the FDE module.

This diagram supplements the subsequent register definitions and can be used for functional configuration and data reading development.
III. Circuit Engineering
3.1 Circuit Source Project
To obtain the circuit source project, please check the link below:
https://mysentech.com/productinfo/118983.html
3.2 Module Usage Instructions
3.2.1 Module Test Environment Setup and Precautions
When using this module, note that the sensor should be attached to the refrigerator fin after pasting 3M double-sided tape on its back, and it should be closely attached to the refrigerator fin:

We can use ice blocks or ice surfaces of different thicknesses to fit the sensor's sensing area (simulating frost formation on refrigerator fins), observe whether the values change linearly with the frost thickness from 0 to 10mm, and verify the detection accuracy.
3.2.2 Usage of Modbus Poll
Modbus Poll is a general-purpose Modbus master station debugging tool that is compatible with all capacitive sensors in this series that support the Modbus-RTU protocol. It can quickly achieve serial communication debugging between sensors and computers, real-time data reading, and log export, and is a general-purpose upper computer tool for verifying sensor functions and collecting test data. The software supports Modbus RTU/ASCII/TCP/IP protocols, is compatible with various register types and data formats, and its operation process is universal for all sensors in the series.
Before use, you need to complete the software installation and activation first. You can download the installation package through official channels. When opening it for the first time, you can try it for 30 days, or you can enter the registration code to activate it permanently. After connecting the sensor to the computer via hardware, open the software and click "Connection" - "Connect". In the pop-up window, configure the serial port parameters (Port Number, Baud Rate, Data Bits / Parity Bits / Stop Bits; sensors in this series default to 9600 Baud, 8N1 format, with the specific details subject to the corresponding model specification). After confirmation, you can establish a communication connection.

The following is a description of the general operating procedure:
- Serial Connection Configuration: After connecting the sensor to the computer via a USB-to-serial module, open the Modbus Poll software, click on the menu bar "Connection" - "Connect", select the COM Port Number corresponding to the sensor in the pop-up window, and configure the serial port parameters that match the sensor (Baud Rate, Data Bits, Parity, Stop Bits; sensors in this series default to 9600 Baud, 8N1 format). After confirmation, the communication connection can be established.
- Import Sensor Configuration File: The software supports importing the corresponding
.mbppre-configured files for each sensor model. The register address, data format, and alias definition have been pre-set in the file, eliminating the need for manual register configuration. Simply open the corresponding sensor's.mbpfile in the software, and all parameters will be automatically loaded. After a successful connection, the real-time detection data of the sensor (such as dust/rain/frost thickness values, status flags, etc.) will be directly displayed. - Data Logging (Optional): If you need to save test data, you can configure logging rules through the "Setup" - "Excel Log" function, which supports logging data at fixed intervals or every time data is updated, and allows you to set an upper limit on the number of records, facilitating subsequent analysis and verification of sensor data.
The above are the general basic operations of the host computer. For the pre-configured files, specific register definitions, and special configuration details of the .mbp of different sensor models, please refer to the content in "VII. Related Materials".
3.3 Application Experiment
Here, we use the GraftPort-RP2040 development board for testing, and the FDE Sensor Frost and Ice Sensor uses the UART interface to communicate with the main controller.
Here, we first use the HY2.0-4P connection cable to connect the module through the XH2.54-4P to HY2.0-4P interface module to the GraftPort-RP2040 development board's UART0 interface:

This diagram shows the connection schematic between the FDE Sensor and GraftPort-RP2040 development board.
Module connections are shown in the following table:
Development Board Pins | Module Pin | Description |
Pin 16 |
|
|
Pin 17 |
|
|
Here, we need to search for relevant driver packages on uPyPI: https://upypi.net/zh/

This figure demonstrates the process of finding the FDE module driver package in uPyPI.
Enter fde_frost_driver to search, and the results are as follows:

This figure shows the search results for fde_frost_driver, facilitating the confirmation of driver package information.
Click to copy the local installation command:

This figure shows the copy interface for the driver installation command, facilitating direct import into the driver library.
Import module driver library code via mip tool, the following are the usage instructions for mpremote tool:
mpremote mip install https://upypi.net/pkgs/fde_frost_driver/1.0.0After importing FDE Sensor Frost and Ice Sensor - MicroPython Driver Code , copy the following main.py code into our project:
# Python env : MicroPython v1.23.0
# -*- coding: utf-8 -*-
# @Time : 2026/4/7 5:30 PM
# @Author : hogeiha
# @File : main.py
# @Description : FDE frost/ice sensor data reading and printing
# ======================================== Import Modules =========================================
# Import the time module, used for delays
import time
# Import the FDE sensor driver class
from fde_frost_sensor import FDEFrostSensor
# ======================================== Global Variables ============================================
# ======================================== Functions ============================================
# ======================================== Custom Classes ============================================
# ======================================== Initialization configuration ===========================================
# Wait 3 seconds to ensure the system is stable
time.sleep(3)
# Print the startup banner
print("FreakStudio: FDE Sensor Data Reading")
# Create the FDE sensor object, parameters: slave address 1, UART number 0, TX pin 16, RX pin 17
sensor = FDEFrostSensor(slave_addr=1, uart_id=0, tx_pin=16, rx_pin=17)
# ======================================== Main Program ============================================
# Calibration value: calibrate the no-load capacitance value (currently commented out, can be uncommented when needed)
# sensor.fde_set_calibration(1)
# Print the data header
print("=== FDE Sensor Real-time Data ===")
# Get and print the temperature value (scaled by 10, unit: °C)
print(f"Temperature: {sensor.fde_temperature():.1f} °C")
# Get and print the C1 capacitance value (unit: pF)
print(f"C1 Capacitance: {sensor.fde_c1():.3f} pF")
# Get and print the C2 capacitance value (unit: pF)
print(f"C2 Capacitance: {sensor.fde_c2():.3f} pF")
# Get and print the C3 capacitance value (unit: pF)
print(f"C3 Capacitance: {sensor.fde_c3():.3f} pF")
# Get and print the sum of the C2 and C3 capacitance (unit: pF)
print(f"C2+C3 Sum: {sensor.fde_c2_c3_sum():.3f} pF")
# Get and print the no-load capacitance preset value (unit: pF)
print(f"No-load Capacitance Preset: {sensor.fde_no_load_cap()}")
# Get and print the hardware version number
print(f"Hardware Version: {sensor.fde_hw_ver()}")
# Get and print the firmware version number
print(f"Firmware Version: {sensor.fde_fw_ver()}")
# Print the ending separator line
print("============================")Burn the code, open the terminal, and the output is as follows:

This figure shows the output results of the FDE example program, which can verify the temperature and multi-channel capacitance reading functions.
4. Driver
fde_frost_driver.zip 45 KB
5. BOM & Recommended Alternatives
None.
6. Change History
Document Version | Modification Date | Modifier | Modified Content |
v1.0 | 2026-04-24 | Hou Junhan | Initialize Document |
v1.1 | 2026-05-20 | Li Zisheng | Add Introduction, 3.2.2 Usage of Modbus Poll |
VII. Related Materials
FDE+Sensor_Frost_and_Ice_Sensor_Product_Brief-Minyuan_202512-2.pdf 733 KB